What was found
FUSELAGE INTERIOR STATION 360 LBL 62 TO RBL 62 FLOORBEAM HAS CORROSION. CORROSION OUT OF LIMITS IAW SRM 51-10-6. REMOVED FLOORBEAM CAP IAW SRM 51-30-2. FABRICATED REPAIR IAW SRM 53-10-8. INSTALLED FLOORBEAM REPAIR IAW SRM 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE INTERIOR STATION 360 LBL 62 TO RBL 62 FLOORBEAM HAS CORROSION. CORROSION OUT OF LIMITS IAW SRM 51-10-6. REMOVED FLOORBEAM CAP IAW SRM 51-30-2. FABRICATED REPAIR IAW SRM 53-10-8. INSTALLED FLOORBEAM REPAIR IAW SRM 51-30-2. (M)