What was found
AFTER TAKEOFF, 'LE SLAT ASYM' MESSAGE SHOWN ON EICAS CAUSED AIR RETURN. MAINTENANCE BITE PSEU, FOUND L/E SLAT S282 (NR 1) AND S302 (NR 10) 2 SENSORS FAILURE. REPLACED TWO EACH SENSORS, PN 834403 AND OPERATIONAL CHECK, CONDITION IS NORMAL.