What was found
TEC TECH REP AT FACILITY TO C/W TU 202. SECOND STAGE NOZZLE INSTALLATION AFTER REMOVAL OF MODULES 2 AND 3 HEARD PIECES INSIDE ENGINE. UPON TEAR-DOWN OR SEPARATION OF MODULES 2 AND 3 FOUND DIFFUSER TO HAVE HOLE IN IT, 2 INCHES BY 6 INCHES. PARTS HAD LIBERATED THEMSELVES. THIS NOW IS NOT A FIELD REPAIR, SO MO2 AND MO3 SENT TO FACTORY FOR EVALUATION. LOG CARDS/LOG BOOK DOES NOT INCLUDE TSN OR TSO OF DIFFUSER, BUT MO3. TSN HOURS - 3,975.1. CYCLES, 8,194.2. TSO HOURS = 1,049. CYCLES, 2,167.4. WAITING FOR EVALUATION REPORT.