SDR 99ZZZX3322

Service difficulty report · Bearing · Amd FALCON10

Difficulty date
July 15, 1999
Submitted
March 26, 2000
Operation
General aviation
Aircraft
N282T
Make and model
Amd FALCON10
Aircraft serial
042
Part
Bearing
Condition
Failed
Location
Starter/Gen
Component
Ge · 2CM504D2D
Stage of operation
NR
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

OVERVOLTAGE CONDITION RESULTING IN OVERHEATING AND PARTIAL INTERNAL FAILURE OF STARTER/GENERATOR. SUBMITTER RECOMMENDED BEARING INSPECTION INTERVAL TO BE INCLUDED IN FALCON MOUNT MANUAL TIME LIMIT (CHAPTER 5-20-00). SUSPECT BEARING FAILURE CAUSED OVERVOLTAGE CONDITION CAUSING INTERNAL FAILURE OF COMPONENT.