What was found
DURING ACCOMPLISHMENT OF ROUTINE 'C' CHECK WORK CARD, FOUND CORROSION ON FLOORBEAM AT BS 360 LBL 62 TO RBL 62. REMOVED FLOORBEAM UPPER CHORD PER SRM 51-30-2. FABRICATED AND INSTALLED NEW UPPER CHORD PER 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ACCOMPLISHMENT OF ROUTINE 'C' CHECK WORK CARD, FOUND CORROSION ON FLOORBEAM AT BS 360 LBL 62 TO RBL 62. REMOVED FLOORBEAM UPPER CHORD PER SRM 51-30-2. FABRICATED AND INSTALLED NEW UPPER CHORD PER 53-10-8.