SDR 99ZZZX571

Service difficulty report · Sensor · Doug DC1030

Difficulty date
January 7, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N140AA
Make and model
Doug DC1030
Aircraft serial
46712
Part
Sensor
Condition
Malfunctioned
Location
Nr 3 Engine
Stage of operation
CR
Nature of condition
M
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HNL - FLT 09 - LOG PAGE: 4917181. DURING CRUISE (WITH NR 2 PNEU SELECTOR PLACARDED INOP AND NR 1 PNEU SYS TEMP HI LIGHT ILLUMINATED. PERFORMED EMERG CHKLST AND DOWNLOADED TO 2-PACK OPERATION (NR 1 AND NR 3 PACKS ON, SUPPLIED BY NR 3 PNEU SYS. WHEN NR 1 PNEU SELECTOR TURNED OFF, TEMP AND PRESS DECREASED. TEMP 265 DEREES CELSIUS PRESS 45 PSI). NR 3 PNEU SYS PRESS INDICATION DROPPED TO ZERO AND BEGAN FLUCTUATING BETWEEN ZERO - 60 PSI. APPEARED TO BE ONLY INDICATION AS NR 1 PRESS REMAINED CONSTANT AND CABIN RATE NEVER FLUCTUATED. REMOVED AND REPLACED NR 1 ENG FAN AIR VALVE TEMP CONTROL SENSOR. REMOVED AND REPLACED PNEU CONTROLLER. OPS LEAK AND CHECK OK. REF: OPER CNTRL NR HALA9900009 AND 99ZZZX572.

More about the Doug DC-10-30