SDR 99ZZZX572

Service difficulty report · Controller · Doug DC1030

Difficulty date
January 7, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N140AA
Make and model
Doug DC1030
Aircraft serial
46712
Part
Controller
Part number
059C709
Condition
Malfunctioned
Location
Nr 3 Engine
Stage of operation
CR
Nature of condition
M
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HNL - FLT 09 - LOG PAGE: 4917181. DURING CRUISE (WITH NR 2 PNEU SELECTOR PLACARDED INOP AND NR 1 PNEU SYS TEMP HI LIGHT ILLUMINATED. PERFORMED EMERG CHKLST AND DOWNLOADED TO 2-PACK OPERATION (NR 1 AND NR 3 PACKS ON, SUPPLIED BY NR 3 PNEU SYS. WHEN NR 1 PNEU SELECTOR TURNED OFF, TEMP AND PRESS DECREASED. TEMP 265 DEREES CELSIUS PRESS 45 PSI). NR 3 PNEU SYS PRESS INDICATION DROPPED TO ZERO AND BEGAN FLUCTUATING BETWEEN ZERO - 60 PSI. APPEARED TO BE ONLY INDICATION AS NR 1 PRESS REMAINED CONSTANT AND CABIN RATE NEVER FLUCTUATED. REMOVED AND REPLACED NR 1 ENG FAN AIR VALVE TEMP CONTROL SENSOR. REMOVED AND REPLACED PNEU CONTROLLER. OPS LEAK AND CHECK OK. REF: OPER CNTRL NR HALA9900009 AND 99ZZX571.