Service difficulty report · Shutoff Valve · Gulstm 200

Difficulty date
May 23, 2014
Submitted
June 10, 2014
Operation
Air carrier
Aircraft
N415PR
Make and model
Gulstm 200
Aircraft serial
017
Aircraft time
4,480 hours, 2,465 cycles
Part
Shutoff Valve
Part number
ZMV24
Part serial
001273
Condition
Failed
Location
Fuel System
Stage of operation
IN
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THE CREW REPORTED THAT DURING PREFLIGHT CHECKS IT WAS DISCOVERED THAT THE LT ENG FIRE SHUTOFF VLV NOT INDICATING CLOSED. THE DEFECTIVE VLV SN 001273 WAS REMOVED FROM SERVICE & AN OVERHAULED UNIT WAS INSTALLED. LEAK & FUNCTIONAL CHECKS WERE SATISFACTORY.