As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HYD 2 LOW PRESS EICAS MESSAGE IN FLIGHT, HYD PAGE INDICATES 0 PERCENT QUANTITY, EDP NR 2 RAN FOR 45 MINUTES WITH ZERO QUANTITY, DIVERTED TO LNK. REPLACED NR 2 EDP AND EDP PSI LINE AT PYLON. CHECK HYD FILTER FOR METAL. NONE NOTED. BLEED SYSTEM. LEAK AND OPS CHECK GOOD. (M)