What was found
FOUND FRAME 700 DAMAGED BETWEEN STRINGERS 16L AND 18L. REMOVED DAMAGED SECTION OF FRAME 700 FROM STRINGER 14L TO EXISTING SPLICE AT STRINGER 20L. FABRICATED SPLICE DOUBLER FROM 2024-T3 .040 INCH. INSTALLED SECTION OF FRAME P/N 600-360290-35 AND SPLICE DOUBLER IAW WVAC EO 601R-53-4653A. (M)