What was found
FOUND FLOORBEAM ANGLES CRACKED AT FS 280, WL 73.50, LBL 9 AND RBL 9, FLOOR LEVEL. REMOVED OLD FLOOR SUPPORT ANGLES AT FS 280 WL 73.50 INBOARD SIDE OF LBL 9 AND RBL 9. INSTALLED NEW ANGLES PART NR RH 601R31113-58, LH 601R31113-57. ALL WORK IAW CRJ200 SRM 51-23-00, 51-25-21, 51-40-11, 51-42-21, 51-21-11, 51-25-16, AND 51-42-06. (M)