What was found
PASSENGER DOOR STAIR STRUCTURE AFT ANGLE IS CRACKED .80 INCH LONG IN AREA OF DOOR ASSIST CABLE PULLEY BRACKET LOCATED IN RADIUS OF ANGLE. CUT AWAY DAMAGED SECTION OF DRAG ANGLE, FABRICATED REPLACEMENT DRAG ANGLE FROM 5773 EXTRUSION AND SPLICE ANGLES FROM $6144-14 ANGLE. INSTALLED ANGLES IAW BRAS EO 601R-52-5101A AND CRJ SRM 51-23-00. (M)