What was found
WHILE ACCOMPLISHING SB 601R-57-037, THE NR 18 HOLE AT WS 148 LT WAS FOUND TO BE ELONGATED TO .280 INCH. REPAIRED ELONGATED HOLE AT LT WS 148 BY INSTALLING FREEZE PLUG IAW BRAS REO 601R-57-5757. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE ACCOMPLISHING SB 601R-57-037, THE NR 18 HOLE AT WS 148 LT WAS FOUND TO BE ELONGATED TO .280 INCH. REPAIRED ELONGATED HOLE AT LT WS 148 BY INSTALLING FREEZE PLUG IAW BRAS REO 601R-57-5757. (M)