What was found
RIGHT OUTBOARD FLAP VANE, OUTBOARD FLAP VANE FITTING WORN EVEN WITH LEADING EDGE OF VANE .030 INCH IS MINIMUM CLEARANCE ALLOWED PER BOMBARDIER, INC REO 601R-57-53-195. REMOVED OLD VANE FITTING FROM RIGHT OUTBOARD FLAP AS WS 296.073 AND INSTALLED NEW VANE FITTING P/N 601R14560-6 IAW BOMBARDIER, INC REOS 601R-57-53-019 AND 601R-57-53-195. (M)