What was found
FOUND INTERCOSTAL ATTACH FLANGE IS CRACKED .3 INCH AT FS 484, LBL 36, WL 73. CUT AWAY DAMAGED FLANGE FABRICATED REPAIR ANGLE USING 56144-14 PREFORMED ANGLE 2024-T42-063 WET INSTALLED ANGLE AIW REO 601R-53-41-059. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND INTERCOSTAL ATTACH FLANGE IS CRACKED .3 INCH AT FS 484, LBL 36, WL 73. CUT AWAY DAMAGED FLANGE FABRICATED REPAIR ANGLE USING 56144-14 PREFORMED ANGLE 2024-T42-063 WET INSTALLED ANGLE AIW REO 601R-53-41-059. (M)