What was found
FOUND FS 460 FLOOR SUPPORT FITTING CRACKED OUTBOARD SIDE OF RBL 9, APPROX 1 INCH LONG. MAINTENANCE REMOVED AND REPLACED FITTING P/N 600-31068-19 AT FS 460.0 RBL 9,0 IAW CRJ SRM 51-40-11, 51-42-06 AND 51-42-21. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FS 460 FLOOR SUPPORT FITTING CRACKED OUTBOARD SIDE OF RBL 9, APPROX 1 INCH LONG. MAINTENANCE REMOVED AND REPLACED FITTING P/N 600-31068-19 AT FS 460.0 RBL 9,0 IAW CRJ SRM 51-40-11, 51-42-06 AND 51-42-21. (M)