What was found
LT AND RT FS 625.00 OBLIQUE ANGLES ARE CRACKED .5 INCH LONG ON AFT RADIUS. (K) MAINTENANCE DRILLED OFF, REMOVED CRACKED OBLIQUE ANGLES LT AND RT FS 625 DRILLED UP, ALODINED AND INSTALLED ANGLES PN 601-35012-51 (LT AND 601-35012-529 (RT). OBLIQUE ANGLES INSTALLED WET USING PR1422BY2 SEALANT AND MS2D470AD-5 AND -6 SOLID RIVETS, PRIMED AND PAINTED. (K)