As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FS 280.0 FLOOR SUPPORT ANGLE PN 600-34017-595 CRACKED APPROX .2 INCHES LONG ON AFT SIDE FS 280.0 OB OF LBL 9.0. (K) [SUP 05-17-07] MAINTENANCE REPAIRED DAMAGED SECTION, DRILLED NEW SECTION OF ANGLE AND SPLICES IAW REO 601R-53-11-136 STEPS 1-6 ANGLE P/N 600-34017-595. (M)