What was found
CRACK FOUND ON MACHINED FITTING, FS 461, RBL 9, OTBD MACHINED FLOOR SUPPORT FITTING AT FS 461, RBL 9, WL 72.00. REPLACED IAW SRM 51-42-21 AND DWG 601R31118. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK FOUND ON MACHINED FITTING, FS 461, RBL 9, OTBD MACHINED FLOOR SUPPORT FITTING AT FS 461, RBL 9, WL 72.00. REPLACED IAW SRM 51-42-21 AND DWG 601R31118. (K)