MWC 133218 - ATTACH FITTING CRACKED AT INTERCOSTAL F/S 484.0 RBL 27.0 UNDER FLOOR STRUCTURE. FITTING REPLACED AT INTERCOSTAL FS 484.0, RBL 27.0 IAW CRJ 200 SRM 51-42-10, 51-42-21. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MWC 133218 - ATTACH FITTING CRACKED AT INTERCOSTAL F/S 484.0 RBL 27.0 UNDER FLOOR STRUCTURE. FITTING REPLACED AT INTERCOSTAL FS 484.0, RBL 27.0 IAW CRJ 200 SRM 51-42-10, 51-42-21. (K)