As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GENERATOR 2 AND IDG CAUTION MESSAGE ON CLIMB-OUT, COMPLIED WITH QRH. SERVICED NR IDG IAW 12-12-24, REPAIRED RT ENGINE IDG TEMP BULB GROUND WIRE (P22EZ) IAW ESPM 20. CONNECTED IDG NR 2 IAW AMM 24-11-01. OPS CHECK GOOD AT THIS TIME. IDG NR 2 TOOK 13 PUMPS. (K)