As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MWC 132430-218 - CARGO BAY DOOR FLOOR SILL CRACKED AT FS 574.00 (1X.10 INCH + 0.120 INCH LENGTH) CARGO BAY FLOOR SILL CUTOUT AND PARTS FABRICATED IAW CRJ 200 REO 601R-53-61-1741. E/C PERFORMED, AMO 9-86. NO CRACK FOUND. PARTS ARE INSTALLED IAW CRJ200 REO 601-53-61-1741. (K)