What was found
HYD SYS NR1 QUANTITY DROPPED TO 25 PERCENT IN FLIGHT. REMOVED AND REPLACED ENG DRIVEN HYD PUMP NR 1 IAW AMM 29-11-01. OPS AND LEAK CHECKS GOOD. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HYD SYS NR1 QUANTITY DROPPED TO 25 PERCENT IN FLIGHT. REMOVED AND REPLACED ENG DRIVEN HYD PUMP NR 1 IAW AMM 29-11-01. OPS AND LEAK CHECKS GOOD. (K)