What was found
CLIP CRACKED AT FS 484.00 AND RBL 27.00 UNDER FLOOR CLIP FABRICATED AT FS484.00 AND RBL 27.00 UNDER FLOOR IAW SRM 51-24-21. NEW CLIP INSTALLED IAW REO 601R-53-41-059 REV A, RESTORE FINISH IAW SRM 51-21-16. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLIP CRACKED AT FS 484.00 AND RBL 27.00 UNDER FLOOR CLIP FABRICATED AT FS484.00 AND RBL 27.00 UNDER FLOOR IAW SRM 51-24-21. NEW CLIP INSTALLED IAW REO 601R-53-41-059 REV A, RESTORE FINISH IAW SRM 51-21-16. (K)