What was found
FS 625 RT, LT OBLIQUE ANGLES ARE CRACKED, W/L 97.50, STRINGER 13 LWR B/L47, L/R CRACK IN ANGLE .7500 INCH LON EACH ONE. REMOVED DAMAGED OBLIQUE LT AND RT ANGLE FS625 IAW REO 601R-53-61-985 AND SRM 51-40-11, MATCHED DRILL 3 EA NEW ANGLES PN 601-35012-51, 601-35012-52 IAW REO 601R-53-61-985, INSTALLED 2 EA ANGLES IAW SRM 51-40-11 AND REO 601R-53-61-985.