What was found
CRACK AT STA 280 IN FLOORBOARD SUPPORT AT APPROX 12 LBL CUT AWAY DAMAGE SECTION AT STA 280 IN FLOORBOARD SUPPORT ANGLE AND INSTALLED NEW REPAIR ANGLE AND SPLICE ANGLES IAW REO 601R-53-11-138, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK AT STA 280 IN FLOORBOARD SUPPORT AT APPROX 12 LBL CUT AWAY DAMAGE SECTION AT STA 280 IN FLOORBOARD SUPPORT ANGLE AND INSTALLED NEW REPAIR ANGLE AND SPLICE ANGLES IAW REO 601R-53-11-138, REV A.