As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT OTBD FLOOR SUPPORT IS CORRODED IN TWO PLACES ALONG RBL 47 AT FS 449.85 AND FS 473.15. BLENDED RT OTBD FLOOR SUPPORT ALONG RBL47 AT FS 449.85 AND FS 473.15. FOUND TO BE WITHIN LIMITS WITH DEEPEST BLEND .003 MAX BLEND DEPTH OF .015 IAW REO 601R53-41-666, REV B.