What was found
ATTACH FITTING CRACKED AT UPPER RADIUS STR 17 AT FS 605. INSTALLED SERVICEABLE CARGO DOOR SILL ANGLE AT FS 605 IAW SRM 51-41-00, 51-42-21 & 51-41-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ATTACH FITTING CRACKED AT UPPER RADIUS STR 17 AT FS 605. INSTALLED SERVICEABLE CARGO DOOR SILL ANGLE AT FS 605 IAW SRM 51-41-00, 51-42-21 & 51-41-04.