What was found
FRAME FS 499 HAS GOUGES AT STR 5 RT. HAND BLENDED GOUGES AT FS 499 AT STR 5R FOUND TO BE WITHIN LIMITS ORIGINAL .050 REMOVED, .004 REMAINING .0146 USING THICKNESS TESTER IAW SRM 51-12-00, 53-41-15, 51-21-11 AND 51-25-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME FS 499 HAS GOUGES AT STR 5 RT. HAND BLENDED GOUGES AT FS 499 AT STR 5R FOUND TO BE WITHIN LIMITS ORIGINAL .050 REMOVED, .004 REMAINING .0146 USING THICKNESS TESTER IAW SRM 51-12-00, 53-41-15, 51-21-11 AND 51-25-06.