What was found
LEFT MLG DOOR INNER SKIN AND FASTENER CHAFED. BLENDED CHAFE AREA WITHIN LIMITS ORG .040, REMOVED .002, REMAINING .038 IAW SRM 52-82-00, FIG 101. BLENDED AREA NR 5 FOUND TO BE OUT OF LIMITS. REPAIRED IAW REO 601R-52-82-337, R & R CHAFE FASTENER.