What was found
SERVICE DOOR THRESHOLD HAS CORROSION ON UPPER MOUNTING HOLES. REPLACED UNSERVICEABLE SERVICE DOOR THRESHOLD (BLENDED 0.062, 0.042" MATERIAL REMAINING WITH SERVICEABLE SERVICE DOOR THRESHOLD IAW SRM 53-00-00, FIG 102, SRM 51-40-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SERVICE DOOR THRESHOLD HAS CORROSION ON UPPER MOUNTING HOLES. REPLACED UNSERVICEABLE SERVICE DOOR THRESHOLD (BLENDED 0.062, 0.042" MATERIAL REMAINING WITH SERVICEABLE SERVICE DOOR THRESHOLD IAW SRM 53-00-00, FIG 102, SRM 51-40-11.