What was found
FLAP FAIL AT ZERO DEGREES DURING EXTENSION AT 192 KTS AND -11 DEGREES C. BTMS 1, 2, 4, 3. PERFORMED FLAP RESET IAW AWAC AMM SUP 98-18E BOX 12 & FLAPS RESET, PLACARD & PLACED ON MEL. M/C PREV HISTORY, 1-20 REMOVED AND REPLACED RT PBSU, 12-30 CLEANED RT BPSU OF EXCESSIVE GREASE, REF WO 196224 FOR R/R OF LT/RT FLAP ACT AND CLEANED AND LUBED FLAP DRIVE SHAFTS OP CHECK GOOD R/P/MEL SEE WO FOR RII'S.