What was found
AT ROTATION, DURING T/O, RECEIVED WOW INPUT CAUTION FOLLOWED BY WOW OUTPUT CAUTION + WOW OUTPUT FAIL STATUS + PROX SYS FAULT STATUS MSG'S. UPON LANDING RECEIVED NUMEROUS OTHER CAUTION + STATUS FAULT MSG'S. QRH C/W AND NWS INOP CAUTION MSG. INSPECTED MLG AND DOOR HARNESSES FOUND PSEU FAILED "NO COM". REMOVED AND REPLACED PSEU PER AMM 32-62-01 OPS CHECK GOOD. MC SEE LP 242378/4 ALSO REPLACED CARGO DOOR HARNESS AS A PRECAUTIONARY MEASURE.