What was found
FLOOR BEAM AT FS 349 JUST INBD OF PAX DOOR HAS CORROSION. CORROSION REMOVED FROM STATION 349 FLOOR BEAM IAW CRJ200 SRM 51-21-06. REPLACED UNSERVICEABLE AFT SUPPORT BRACKET WITH SERVICEABLE SUPPORT BRACKET.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR BEAM AT FS 349 JUST INBD OF PAX DOOR HAS CORROSION. CORROSION REMOVED FROM STATION 349 FLOOR BEAM IAW CRJ200 SRM 51-21-06. REPLACED UNSERVICEABLE AFT SUPPORT BRACKET WITH SERVICEABLE SUPPORT BRACKET.