What was found
SERVICE DOOR LWR FWD FLOOR SUPPORT CLEAT ON CUT OUT AT FS 320.00 & RBL43 IS CORRODED. R & R LWR FWD FLOOR SUPPORT CLEAT WITH NEW SERVICEABLE PART IAW SRM 51-42-21 & 51-40-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SERVICE DOOR LWR FWD FLOOR SUPPORT CLEAT ON CUT OUT AT FS 320.00 & RBL43 IS CORRODED. R & R LWR FWD FLOOR SUPPORT CLEAT WITH NEW SERVICEABLE PART IAW SRM 51-42-21 & 51-40-11.