Service difficulty report · Fuel Sys · Cndair CL6002B19

Difficulty date
December 18, 2015
Submitted
December 23, 2015
Operation
Air carrier
Aircraft
N410AW
Make and model
Cndair CL6002B19
Aircraft serial
7490
Aircraft time
35,246 hours, 41,987 cycles
Part
Fuel Sys
Condition
Leaking
Location
Apu
Stage of operation
TX
How discovered
O
Nature of condition
K, B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER START OF APU ON THE GND, STRONG FUEL ODOR FILLED THE CABIN, ODOR DISSIPATE UPON APU SHUTDOWN. INSPECTED AFT EQUIPMENT BAY & APU ENCLOSURE DRAINS, FOUND FUEL LEAKING FROM RT ENCLOSURE DRAIN WHILE APU PUMP IS ON. APU LEAK NOTED LEFT OF COMBUSTOR DRAIN ON COMBUSTION CASE, OIL IN APU, HAS FUEL CONTAMINATION. R & R APU ASSEMBLY IAW MX TASK CARD 00-49-310-01AW. OPERATIONS CHECKED GOOD.