Service difficulty report · Modulating Valve · Cndair CL6002B19
FAA SDR system
- Difficulty date
- February 20, 2016
- Submitted
- February 22, 2016
- Operation
- Air carrier
- Make and model
- Cndair CL6002B19
- Aircraft serial
- 7640
- Aircraft time
- 32,778 hours, 31,355 cycles
- Part
- Modulating Valve
- Condition
- Faulty
- Location
- Anti-Ice System
- Stage of operation
- TO
- How discovered
- O
- Nature of condition
- J
- Precautionary procedure
- C
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WING OVERHEAT WARNING ON TAKEOFF ROLL. ABORTED TAKEOFF AT 110 KTS. MAX BTMS READS 4545, ACARS REPORTS LT WING DUCT OVERHEAT. WING & COWL ANTI-ICE WERE ON & MSG CLEARED AFTER THROTTLES RETARDED. COMPLIED WITH CM ACTION PLACARDED & PLACED ON MEL. R & R LT 14TH STAGE MODULATING VLV IAW AMM 30-12-04. OPERATIONS CHECKED GOOD, REMOVED PLACARD & FROM MEL.