What was found
CREW REPORTED THAT THE FLOOR LEVEL EMERGENCY LIGHTS WERE NOT ILLUMINATING FROM ROW 8 AFT. INSPECTED CONNECTIONS OF EMERGENCY LIGHTS, CLEANED BARREL CONNECTORS AT ROW 12 AND ASSEMBLED LIGHTS IAW AMM 33-51-01, EMERGENCY LIGHTS OPS CHECKED GOOD IAW AMM 33-51-00.