What was found
EMERGENCY LIGHTS ROW 8 AND AFT WILL NOT ILLUMINATE. FOUND COVER CRACKED AND WIRES CUT AT ROW 12. REPAIRED THE WIRES AND R & R THE CONNECTORS V77890 AND CABLE V32890 IAW ESPM 20-17 AND AMM 33-51-01. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTS ROW 8 AND AFT WILL NOT ILLUMINATE. FOUND COVER CRACKED AND WIRES CUT AT ROW 12. REPAIRED THE WIRES AND R & R THE CONNECTORS V77890 AND CABLE V32890 IAW ESPM 20-17 AND AMM 33-51-01. OPS CHECKED GOOD.