What was found
L/H I/B FLAP VANE L/E BETWEEN FLAP STA 69.631-FLAP STA 79.257 HAS GOUGE DAMAGE. AIRCRAFT REMOVED FROM SERVICE CUT OUT DAMAGED SKIN ON L/H I/B FLAP VANE AT FLAP STA 77.5 . CUTOUT DIMENSIONS ARE 1.3"W X .7"L . FABRICATED FLAP VANE INSERT AND VANE BUTT STRAP FROM 2024-T3 .050" REF CRJ 200 SRM 57-52-00 AND SRM 51-24-16 REV 37 LOCATED AND DRILLED HOLES AND COMMON TO THE VANE INSERT, BUTTSTRAPS, AND L/H I/B FLAP VANE AT FLAP STA 77.5 REF CRJ 200 SRM 57-52-00 REV 37 SRM 51-40-11-11. INSTALLED REPAIR PARTS ON L/H I/B FLAP VANE AT FLPA STA 77.5 REF CRJ-200 SRM 57-52-00 AND 51-42-13 REV 37.