What was found
CORROSION ON FLOOR SILL PANEL STATION 467, AND LBL 42. AIRCRAFT REMOVED FROM SERVICE. REMOVED CORROSION ON FLOOR SILL PANEL AT STATION 467, AND LBL 42, REF CRJ 200 SRM 51-21-06. MEASURE OF REWORK AREA L=0.950" W=0.780" D=0.006", ORIGINAL THICKNESS 0.055", REF CRJ 200, SRM 53-41-45. REMAINING THICKNESS AFTER REWORK IS 0.490", REWORK AREA FOUND TO BE WITHIN LIMITS, REF REPAIR ENGINEERING ORDER (REO) 601R-53-41-666 REV C DATED 2012-11-06.