What was found
MAIN ENTRY DOOR HAS A CRACK ON THE FORWARD SIDE PANEL OF UPPER STEP FS320.10. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED DAMAGE OF MAIN ENTRY DOOR FORWARD SIDE PANEL OF UPPER STEP FS320.10, DIMENSIONS L= 12.00Ï¿½ X W= 6.00Ï¿½. FABRICATED 1 WEB REPLACEMENT L=13.00Ï¿½ X W= 3.50Ï¿½ AND 3 DOUBLERS DIMENSIONS, L=12.00Ï¿½ X W=8.50Ï¿½, L= 6.00Ï¿½ X W=3.50Ï¿½ AND L= 6.00Ï¿½ X W=3.50Ï¿½. PERFORMED HFEC TO CUTOUT EDGES AND FABRICATED PARTS WITH NO INDICATIONS. RESTORED PROTECTIVE FINISH. ALL WORK WITHIN LIMITS WAS PERFORMED AWA SUPPLEMENTAL NO. 13-134 DATE OF ISSUE 12/9/2013. WORK PERFORMED UNDER AERSALE WORK ORDER 003500, CARD NO. 20478, TT: 39682:59 TC: 38340.