What was found
PRESSURE FLOOR PANEL AT FS. 559.00, LBL 42, HAS CORROSION ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FROM PRESSURE FLOOR PANEL AT FS. 559.00, LBL 42, BLENDED AREA MEASURES 2.17Ï¿½ L X .73Ï¿½ W REF BOMBARDIER REO 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012.CALIPER S/N: 61512501 CAL DUE: 08-07-2021. BLEND FOUND TO BE OUT OF LIMITS DUE TO LENGTH OF BLEND. REF BOMBARDIER REO 601R-53-41-666, SHEET 3 STEP 1.1.B REV (C), ISSUE DATE: 11-06-2012. PERFORMED HFEC INSPECTION ON BLENDED AREA OF PRESSURE FLOOR PANEL AT FS. 559.00, LBL 42, REF BOMBARDIER REO 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012 AND CRJ-200 PART (1) NDTM 51-20-06, REV (42). NO INDICATION NOTED. ET TESTER S/N: 60007150515 CAL DUE: 10-09-2021. PERFORMED UT THICKNESS MEASUREMENT ON BLENDED AREA OF PRESSURE FLOOR PANEL AT FS. 559.00, LBL 42, REF BOMBARDIER REO 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012 AND CRJ-200 PART (4) NDTM 51-00-001, REV (42). MINIMUM REMAINING THICKNESS 0.076Ï¿½. UT GAUGE S/N:151136107 CAL DUE: 09-16-2021. EVALUATED BLENDED AREA OF PRESSURE FLOOR PANEL AT FS. 559.00, LBL 42, AND FOUND TO BE WITHIN LIMITS REF ASAP EA# AWAC-CRJ253-01567, REV (IR) ISSUE DATE: 02-02-2021. RESTORED SURFACE PROTECTION TO REWORKED AREA REF ASAP EA# AWAC-CRJ253-01567, REV (IR) ISSUE DATE: 02-02-2021.