What was found
PRESSURE FLOOR ANGLE AT FS. 461.00, LBL 42, HAS CORROSION. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FROM PRESSURE FLOOR ANGLE AT FS. 461.00, LBL 42, BLENDED AREA MEASURES P(1) 1.95Ï¿½ L X 0.900Ï¿½ W, P(2) 0.500Ï¿½ L X 0.180Ï¿½ W, REF REO: 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012. CALIPER S/N: 65512501 CAL DUE: 08-07-2021. PERFORMED HFEC INSPECTION ON BLENDED AREA OF PRESSURE FLOOR ANGLE AT FS. 461.00, LBL 42, REF BOMBARDIER REO: 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012 AND CRJ-200 PART (1) NDTM 51-20-06, REV (42). NO INDICATION NOTED. ET TESTER S/N: 60007150515 CAL DUE: 10-09-2021. PERFORMED UT THICKNESS MEASUREMENT ON BLENDED AREA OF PRESSURE FLOOR ANGLE AT FS. 461.00, LBL 42, REF BOMBARDIER REO 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012 AND CRJ-200 PART (4) NDTM 51-00-001, REV (42). MINIMUM REMAINING THICKNESS P(1) 0.070Ï¿½, P(2) 0.074Ï¿½. UT GAUGE S/N:151136107 CAL DUE: 09-16-2021. EVALUATED BLENDED AREA OF PRESSURE FLOOR ANGLE AT FS. 461.00, LBL 42, AND FOUND TO BE WITHIN LIMITS REF BOMBARDIER REO 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012. RESTORED SURFACE PROTECTION OF REWORKED AREA REF BOMBARDIER REO 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012.