What was found
PRESSURE FLOOR PANEL AT FS. 524.00, RBL 42, HAS CORROSION. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FROM PRESSURE FLOOR PANEL AT FS. 524.00, RBL 42 , BLENDED AREA MEASURES 1.800Ï¿½ L X 1.100Ï¿½ W, REF BOMBARDIER REO: 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012. PERFORMED HFEC INSPECTION ON BLENDED AREA OF PRESSURE FLOOR PANEL AT FS. 524.00, RBL 42 , REF BOMBARDIER REO: 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012 AND CRJ-200 NDTM PART (1). 51-20-06, REV (42). NO INDICATION NOTED. ET TESTER S/N: 60007150515 CAL DUE: 10-09-2021. PERFORMED UT THICKNESS MEASUREMENT ON BLENDED AREA OF PRESSURE FLOOR PANEL AT FS. 524.00, RBL 42 , REF BOMBARDIER REO 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012 AND CRJ-200 NDTM PART (4) 51-00-001, REV (42). MINIMUM REMAINING THICKNESS 0.052Ï¿½. UT GAUGE S/N:151136107 CAL DUE: 09-16-2021. EVALUATED BLENDED AREA OF PRESSURE FLOOR PANEL AT FS. 524.00, RBL 42, AND FOUND TO BE WITHIN LIMITS REF BOMBARDIER REO 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012. RESTORED SURFACE PROTECTION OF REWORKED AREA REF BOMBARDIER REO 601R-53-41-666, REV (C), ISSUE DATE: 11-06-2012