What was found
2 SPOTS OF CORROSION ON R/H FLOOR SILL PANEL WITHIN 2.50IN OF EACH OTHER FROM FS438.0 TO FS443.0. ***AIRCRAFT REMOVED FROM SERVICE*** BLENDED BOTH SPOTS IAW REO 601R-53-41-666 REV C. DATE 2012-11-06. DIMENSIONS #1 L=1.025IN X W=.900IN X D=.005IN #2 L=1.0IN X W=.800IN X D=.005IN. BLENDED AREAS FOUND TO BE OUT OF LIMITS DUE TO CLOSE PROXIMITY. RE-EVALUATED BLENDED AREAS IAW EA#: CJ253-01697 AND FOUND TO BE ACCEPTABLE. RESTORED PROTECTIVE FINISH, ALL WORK PERFORMED AT AERSALE CRS 4AER685B UNDER WORK ORDER 003442