What was found
CORROSION COMMON TO PRESSURE FLOOR ANGLE AT FS 513.00 TO FS 513.00+4 AND LBL 40 TO LBL 43. ****************AIRCRAFT REMOVED FROM SERVICE************************** BLENDED 2 EACH AREAS: FS 513.00 AT LBL 41 (P1) 1.20"L X .800"W X .004"D; FS 513.00+4 AT LBL 43 (P2) 1.30"L X 1.00"W X .003"D. ORIGINAL MATERIAL THICKNESS IS .080". HFEC PERFORMED AT BOTH BLEND AREAS WITH NO INDICATIONS. RESTORED PROTECTIVE FINISH. RESTORED CIC PROTECTION. ALL WORK WITHIN ALLOWABLE LIMITS IAW BOMBARDIER GREO 601R-53-41-666 REV C DATED 2012-11-06. WORK COMPLETED ON AERSALE W/O #003486 CARD #20154 AT AERSALE CRS4AER685B.