What was found
AFT PRESSURE BULKHEAD AT FS 621 LBL 30.00 TO LBL 32.80 HAS A DENT 2.80"L X 2.20"W .045"D AND A GOUGE AT DENTED AREA MEASURING 1.40"L X 1.00"W X .029"D ON FWD SIDE OF BULKHEAD AT WL 111.63 TO WL 114.43. ************AIRCRAFT REMOVED FROM SERVICE************************** HAND DRESSED DENTED AREA BACK TO ORIGINAL CONTOUR. NO OIL-CANNING NOTED AT REWORKED AREA AT THIS TIME. BLENDED DAMAGED AREA TO A SMOOTH CONTOUR WITH MAX REMAINING THICKNESS = .046". MINIMUM REMAINING THICKNESS = .034". HFEC INSPECTION WAS PERFORMED AT REPAIR AREA WITH NO INDICATIONS. RESTORED PROTECTIVE FINISH. ALL WORK PERFORMED WITHIN ALLOWABLE LIMITS IAW MHIRJ REO 601R-53-61-7759 REV (--) DATED 2021-12-10. WORK COMPLETED ON AERSALE WO #003486 CARD #20111 CRS #4AER685B. TT: 39,961 TC:38,675