What was found
MAINTENANCE FOUND 4 EACH SCRATCHES ON VERTICAL STABILIZER R/H SIDE COMMON TO ACCESS PANEL 325CR. DIMENSIONS OF SCRATCHES ARE: (P1) = 2.500"L X 0.800"W X 0.006"D AND (P2) = 3.00"L X 1.400"W X .007"D (P3) = 1.500"L X 1.300"W X .004"D (P4) = 1.500"L X .500"W X .005"D (P5) = 1.500"L X 1.00"W X .003"D. (P3) WAS FOUND TO BE WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 55-31-31 REVISION 38. (P1,P2,P4, AND P5) ARE NOT WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 55-31-31 REVISION 38. ************AIRCRAFT REMOVED FROM SERVICE************************* BLENDED DAMAGED AREAS TO A SMOOTH CONTOUR. (P1) AND (P2) BLENDS DID NOT SURPASS REMAINING MATERIAL THICKNESS OF .093". ORIGINAL THICKNESS OF .100". (P4) AND (P5) BLENDS DID NOT SURPASS REMAINING MATERIAL THICKNESS OF .035" ORIGINAL THICKNESS OF .040." HFEC INSPECTION PERFORMED WITH NO INDICATIONS. RESTORED PROTECTIVE FINISH. ALL WORK PERFORMED WITHIN ALLOWABLE LIMITS IAW ASAP EA #AWAC-CRJ253-01769 REV A DATED 12/04/2021. WORK COMPLETED ON AERSALE WO #003486 CARD #20474 AT AERSALE CRS #4AER685B. N435AW TT:39,961 TC:38,675.