What was found
CORROSION ON R/H FLOOR STRAP P/N: 601R31025-29 AT FS 559.00+32 AND RBL 27 TO RBL 36. ******************AIRCRAFT REMOVED FROM SERVICE********************** BLENDED 2 EACH AREAS ON R/H FLOOR STRAP P/N: 601R31025-29 AT FS 559.00+32: (P1) = 4.5"L X 2.0"W X .019"D (RBL 30) AND (P2) = 2.0"L X 1.5"W X .015"D (RBL 32) AND FOUND NOT WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 53-00-00 REV 39. FABRICATED REPLACEMENT STRAP OUT OF 7075-T6 .050" IAW CRJ200 SRM 53-41-43 REV 39, CRJ200 SRM 53-41-43 REV 39, AND CRJ200 SRM 51-24-21 REV 39. APPLIED PROTECTIVE AND DECORATIVE FINISH ON FABRICATED FLOOR STRAP IAW CRJ200 SRM 51-21-11 REV 39 AND CRJ 200 SRM 51-25-01 REV 39. REMOVED AND REPLACED R/H FLOOR STRAP P/N: 601R31025-29 IAW CRJ200 SRM 51-42-06 REV 39. WORK COMPLETED ON AERSALE WO #003644 CARD #20259 AT AERSALE CRS #4AER685B. N444ZW TT:38,791:53 TC:37,500